Welcome to our website.

WeChat
Pay attention to us
micro-blog
Pay attention to us

Six steps of installation and debugging of press f

publish time:2016-11-29

Press filter installation debugging need to pay attention to what? The following overflow environmental protection filter equipment for you to introduce press filter installation, debugging six strides:

1 press filter should be installed on the smooth concrete foundation. The feed end of the thrust plate foot bolt is fixed on a base; the stent end without bolt, or anchor bolt positioning with two locking nut, proper clearance is left between the nut gasket and foot machine, this machine can trace a telescopic foot. Before installation, the installation staff shall correct the verticality of the large plane of the cross member and the thrust plate.

2. The foundation structure shall be designed by the construction personnel according to the equipment load, and the anchor bolts shall be reserved for two times.

3, filter presses around should have enough operation and maintenance space, hydraulic pressure filter press, select the appropriate place, hydraulic station, to ensure the hydraulic station can work properly.

4, according to the work requirements put the filter board, layout feeding, washing and drainage pipeline. Equipped with filtration pressure indicator and reflux channel for controlling filtration pressure. If the diaphragm is pressed, the compressed air line shall be arranged.

5, hydraulic press, hydraulic oil tank cleaning injection of 20#-40# hydraulic oil, using temperature > - 5 DEG C; if the ambient temperature is low, can use a similar hydraulic oil viscosity, low freezing point. Hydraulic oil must be joined by 80 - 100 mesh screen.

6, mechanical or hydraulic press device, switch on the power, start the motor should work correctly. When the hydraulic pressure is pressing, the pressure gauge should rise steadily, the hydraulic system has no leakage phenomenon, adjust the working pressure of the hydraulic station according to the size of the model correctly. After the test, if the fuel tank is found to be insufficient, it should be supplemented.